Operator error messages for Enigma and Shotmaster (E-XXX)
![]() |
Note |
---|---|
If the message persists, please contact your service organization. |
Number |
Infos messages |
Explanations / Remedies |
---|---|---|
E-000 |
Bean hopper rear missing |
This error is set if the bean hopper rear is removed during a running process. → Check if the rear bean hopper is inserted correctly. |
E-001 |
Bean hopper front missing |
This error is set if the bean hopper front is removed during a running process. → Check if the front bean hopper is inserted correctly. |
E-002 |
Grounds drawer missing |
This error occurs when the grounds drawer is drawn out during a coffee process. |
E-003 |
Motor timeout |
The motor sensors cannot detect movements anymore. |
E-004 |
Motor error |
Severe motor error occurred. |
E-005 |
Motor init error |
If the initialization of the brew group fails three times consecutively this error is set. |
E-010 |
The current software doesn't support the version of this CPU. → Update to the latest software. If the error still doesn't disappear. → Change the CPU. |
The current software doesn't support the version of this CPU. |
E-011 |
Hydraulic unit not connected. Water pump has been switched off. |
- |
E-012 |
Milk unit not connected. Water pump has been switched off. |
- |
E-013 |
Brewing unit not connected. |
- |
E-014 |
Grinder unit not connected. |
- |
E-016 |
Power Configuration is not detected. Please check connector X5 and Power Box. |
- |
E-017 |
Coffee boiler overheating. Machine will go to standby mode. |
- |
E-018 |
Coffee boiler right overheating. Machine will go to standby mode. |
- |
E-020 |
Machine shutdown detected. Over-current or short-circuit on heater power module.
|
- |
E-021 |
The machine detected that the grinder motor was turning endlessly, which could lead to overheating. To protect the machine, the power was switched off. Please contact your service organization. |
- |
E-050 |
Inter CPU communication error. Please restart the machine and contact technical support if the error occurs again. |
- |
E-094 |
The machine was in standby mode as a boiler was overheating. Please contact your service organization. |
- |
E-095 |
Software update running. Please wait... |
Software update is running on the other display. Wait until the software update has been finished. |
E-096 |
Right display deactivated. |
Wrong machine type of the right display. Example: You have an e'4 with two displays and the machine type of the right display is set to e'2 (an e'2 doesn't have two displays). This error can only appear at the right display. |
E-097 |
Please set machine type. |
This error occurs when the machine type of the display doesn't match with the machine type of the CPU. |
E-098 |
Please start software update. |
This error occurs if the software of the display doesn’t match with software on the CPU or the other display. |
E-099 |
Communication Error. Please turn the coffee machine off, wait 10s and turn it on again. |
This error occurs if the connection between the display and the CPU was interrupted for more than 30 seconds. The display will restart automatically after a minute to solve the problem (normally that's enough). But if the error doesn't disappear after the restart: → Turn the coffee machine off (main switch not standby button!), wait 10s and turn it on again. The problem should be solved. |
E-100 |
Pressure Sensor Always Zero. |
- |
E-101 |
Pressure sensor too high |
Steam boiler pressure too high. |
E-102 |
Steam Boiler Empty Timeout. |
If the service function Empty Steam Boiler or Depressurize Steam Boiler is started the steam boiler must be empty/depressurized after 15 minutes. If not, the purge valve must be defective. |
E-103 |
Timeout during steam boiler filling. Please check the water supply and press Continue. |
If it takes too long to fill the steam boiler a timeout occurs and all hot water and steam products are locked. → Check if the water tap is open. → Check the water supply. |
E-104 |
Timeout Steam Heating. |
If the steam boiler is heating too long without reaching the nominal pressure, this error message occurs (after initialization: 20 minutes, during operation: 10 minutes). |
E-105 |
Steam boiler connector missing. |
- |
E-106 |
Steam boiler overheating. Machine will go to standby mode. |
- |
E-107 |
Steam boiler pressure sensor failure. Please check the pressure sensor and cable. |
- |