Automatic cleaning procedure on Enigma (milk and choco modules included)
It is possible to run the complete cleaning procedure at any time. Though you must run the cleaning when requested (if canceled and depending on settings, it will not be possible to make a drink unless cleaning is performed).
![]() |
Warning |
---|---|
DO NOT REMOVE THE MILK TUBES FROM THE MILK TANK before requested on the screen. The milk in the tube will be pushed back. |
-
Press and hold the rinse (1) button for 3 s to run automatic cleaning.
-
Press Yes (or No to cancel).
-
Empty and clean the grounds drawer (procedure is available under the e'Support center (https://support.eversys.com/hc/en-us).
-
If using the undercounter ground coffee disposal (machine option)
-
Remove the black drawer (2) and clean it with soft soap. Rinse, dry and store it for later use.
-
Install the red drawer (3) for the cleaning procedure.
-
-
Press Continue.
-
If milk system detected (machine model)
-
Remove the milk tank (4) and store it in a fridge during the cleaning process.
-
If necessary, empty and clean the milk tank | container and the inside of the fridge.
-
If using 1 litre bottle cleaning solution
-
Remove the bottle cap (5).
-
Fill the empty cleaning tank (6) with Everclean (E'2ms: 25 ml (0.85 oz) | E'4ms and Shotmaster ms: 50 ml (1.7 oz)).
-
-
If using 3 litre bottle cleaning solution
-
Fill the empty cleaning tank (6) with Everclean (E'2ms: 25 ml (0.85 oz) (press pump once) | E'4ms and Shotmaster ms: 50 ml (1.7 oz) (press pump twice)).
-
-
If using milk cleaning tabs
-
Fill the empty cleaning tank (6) with tablets (E'2ms: 1 tablet | E'4ms and Shotmaster ms: 2 tablets).
-
-
Place the milk tube inside the cleaning tank (6). Ensure that it correctly lays at the bottom of the tank.
-
Place the empty cleaning tank inside of the fridge.
-
Press Continue.
-
-
If choco module | powder unit (machine option)
-
Open the door.
-
Turn the powder chutes (7) upwards and remove them.
-
Unplug the tube (8) from the panel.
-
Turn the handle upwards (CCW) (9) to unlock the mixer (10).
-
Gently remove the mixer (10) and the drawer (11).
-
Separate the mixer (tube (8), bowl (12) and bowl cover (13)).
-
Clean all under clean tap water with soft soap. Dry the parts.
-
Assemble the mixer (tube (8), bowl (12) and bowl cover (13)). Put it back to its original position.
-
Lock the handle (9) to lock the mixer (10).
-
Plug the tube (8).
-
Put the drawer (11) back to its original position.
-
Put the powder chutes (7) back to their original position.
-
Close the door.
-
Press Continue.
-
-
Wait for the cleaning to complete.
Warning RISK OF BURNS OR SCALDING
During automatic cleaning, hot cleaning solution and steam are released several times.
Keep hands and skin away from the outlets.
Note It takes approximately:
-
12 minutes to complete the entire process with Everclean or milk cleaning balls.
-
18 minutes to complete the entire process with milk cleaning tabs.
-
-
If milk system detected (machine model)
-
When cleaning is finished, remove and clean the cleaning tank (6).
-
Empty the cleaning tank in a sink.
-
Clean the milk tank tube with a damp single-use cloth and put the milk tank (4) back to its original position.
-
If necessary, fill the milk tank with cold fresh milk.
-
Ensure that milk tank tube correctly lays at the bottom of the tank.
-
Press Continue.
-
-
Empty the grounds drawer in a sink and clean it with soft soap.
Warning RISK OF BURNS OR SCALDING
After first startup or during cleaning, the grounds drawer may contain hot water, empty it carefully.
-
Rinse and dry the grounds drawer.
-
Put the grounds drawer back to its original position.
-
If using the undercounter ground coffee disposal (machine option)
-
Empty the red cleaning drawer (3) in a sink and clean it with soft soap. Rinse, dry and store it for later use.
Warning RISK OF BURNS OR SCALDING
After first startup or during cleaning, the grounds drawer may contain hot water, empty it carefully.
-
Put the black drawer back (2) to its original position.
-
-
Press Yes to acknowledge emptying of the grounds drawer (or No to cancel).
-
Your machine is now clean and ready for use.