Operator error messages for Légacy (E-XXX)
![]() |
Note |
---|---|
If the message persists, please contact your service organization. |
Number |
Infos messages |
Explanations / Remedies |
---|---|---|
E-000 |
Bean hopper 1 missing |
This error is set if the bean hopper 1 is removed during a running process. → Check if the bean hopper 1 is inserted correctly. |
E-001 |
Bean hopper 2 missing |
This error is set if the bean hopper 2 is removed during a running process. → Check if the bean hopper 2 is inserted correctly. |
E-002 |
Grounds drawer missing |
This error occurs when the grounds drawer is drawn out during a coffee process. |
E-003 |
Motor timeout |
The motor sensors cannot detect movements anymore. |
E-004 |
Motor error |
Severe motor error occurred. |
E-005 |
Motor init error |
If the initialization of the brew group fails three times consecutively this error is set. |
E-010 |
The current software doesn't support the version of this CPU. → Update to the latest software. If the error still doesn't disappear. → Change the CPU. |
The current software doesn't support the version of this CPU. |
E-011 |
Hydraulic unit not connected. Water pump has been switched off. |
- |
E-012 |
Milk unit not connected. Water pump has been switched off. |
- |
E-013 |
Brewing unit not connected. |
- |
E-014 |
Grinder unit not connected. |
- |
E-016 |
Power Configuration is not detected. Please check connector X5 and Power Box. |
- |
E-017 |
Coffee boiler overheating. Machine will go to standby mode. |
- |
E-019 |
Heater power module shutdown. Over-current or short-circuit detected.
|
- |
E-020 |
Machine shutdown detected. Over-current or short-circuit on heater power module.
|
- |
E-021 |
The machine detected that the grinder motor was turning endlessly, which could lead to overheating. To protect the machine, the power was switched off. Please contact your service organization. |
- |
E-050 |
Inter CPU communication error. Please restart the machine and contact technical support if the error occurs again. |
- |
E-094 |
The machine was in standby mode as a boiler was overheating. Please contact your service organization. |
- |
E-095 |
Software update running. Please wait... |
Wait until the software update has been finished. |
E-097 |
Please set machine type. |
This error occurs when the machine type of the display doesn't match with the machine type of the CPU. |
E-098 |
Please start software update. |
This error occurs if the software of the display doesn’t match with software on the CPU or the other display. |
E-099 |
Communication Error. Please turn the coffee machine off, wait 10s and turn it on again. |
This error occurs if the connection between the display and the CPU was interrupted for more than 30 seconds. The display will restart automatically after a minute to solve the problem (normally that's enough). But if the error doesn't disappear after the restart: → Turn the coffee machine off (main switch not standby button!), wait 10s and turn it on again. The problem should be solved. |
E-100 |
Pressure Sensor Always Zero. |
- |
E-101 |
Pressure sensor too high |
Steam boiler pressure too high. |
E-102 |
Steam Boiler Empty Timeout. |
If the service function Empty Steam Boiler or Depressurize Steam Boiler is started the steam boiler must be empty/depressurized after 15 minutes. If not, the purge valve must be defective. |
E-103 |
Timeout during steam boiler filling. Please check the water supply and press Continue. |
If it takes too long to fill the steam boiler a timeout occurs and all hot water and steam products are locked. → Check if the water tap is open. → Check the water supply. |
E-104 |
Timeout Steam Heating. |
If the steam boiler is heating too long without reaching the nominal pressure, this error message occurs (after initialization: 20 minutes, during operation: 10 minutes). |
E-105 |
Steam boiler connector missing. |
- |
E-106 |
Steam boiler overheating. Machine will go to standby mode. |
- |
E-107 |
Steam boiler pressure sensor failure. Please check the pressure sensor and cable. |
- |