Operator error messages for Legacy+ (E-XXX)
|
Note |
|---|---|
|
If the message persists, please contact your service organization. |
|
Number |
Infos messages |
Explanations / Remedies |
|---|---|---|
|
E-010 |
The current software doesn't support the version of this CPU. → Update to the latest software. If the error still doesn't disappear. → Change the CPU. |
The current software doesn't support the version of this CPU. |
|
E-011 |
Hydraulic unit not connected. Water pump has been switched off. |
- |
|
E-012 |
Milk unit not connected. Water pump has been switched off. |
- |
|
E-013 |
Brewing unit not connected. |
- |
|
E-014 |
Grinder unit not connected. |
- |
|
E-016 |
Power Configuration is not detected. Please check connector X5 and Power Box. |
- |
|
E-017 |
Coffee boiler overheating. Machine will go to standby mode. |
- |
|
E-019 |
Power board shutdown. Over-current or short circuit on a heater power line.
|
The power board was switched off because an over-current or short circuit was detected in a heater power line. |
|
E-020 |
Power board shutdown detected. Over-current or short circuit on a heater power line.
|
The power board was switched off because an over-current or short circuit was detected in a heater power line. |
|
E-021 |
The machine detected that the grinder motor was turning endlessly, which could lead to overheating. To protect the machine, the power was switched off. Please contact your service organization. |
This may be caused by a defective triac on the power board. |
|
E-022 |
Power board failure. Power board failure detected which could lead to heater damage. Please contact your service organization. |
This may be caused by a defective triac on the power board. |
|
E-023 |
Water pump unit not connected |
- |
|
E-024 |
The power configuration is not compatible with the coffee boiler power. |
- |
|
E-025 |
The power configuration is not compatible with the milk heater power. |
- |
|
E-050 |
Inter CPU communication error. Please restart the machine and contact technical support if the error occurs again. |
This occurs when communication via CAN between the CPUs fails. |
|
E-094 |
The machine was in standby mode as a boiler was overheating. Please contact your service organization. |
- |
|
E-095 |
Software update running. Please wait... |
Wait until the software update has been finished. |
|
E-097 |
Please set machine type. |
This error occurs when the machine type of the display doesn't match with the machine type of the CPU. |
|
E-098 |
Please start software update. |
This error occurs if the software of the display doesn’t match with software on the CPU or the other display. |
|
E-099 |
Communication Error. Please turn the coffee machine off, wait 10s and turn it on again. |
This error occurs if the connection between the display and the CPU was interrupted for more than 30 seconds. The display will restart automatically after a minute to solve the problem (normally that's enough). But if the error doesn't disappear after the restart: → Turn the coffee machine off (main switch not standby button!), wait 10s and turn it on again. The problem should be solved. |